What was found
INSPECTION TYPE:2C CENTER CARGO COMP BILGE AREA FOUND CORROSION AT STA 5-53 TO 5-123 LONGERON 47RH AS MARKED. REMOVED CORRODED LONGERON AND SPLICE, FABRICATED LONGERON AND SPLICE AND INSTALLED IAW SAA TRAVELER 79724800001, 797244810001, AND DWG ASA 7031 AND MD-11 SRM 53-10-00 FIG 2, 51-31-01, AND 51-21-01.