What was found
INSPECTION TYPE:C RT WING FIXED L/E COMPT AT STA XORS 538 APPROX FOUND UPPER DOUBLER CRACKED AS MARKED. DAMAGED AREA AT RT WING FIXED L/E COMPT STA 538 UPPER DOUBLER AREA TRIMMED OFF AS PER SRM 57-10-00 VI FIG 27 R40. NEW REPAIR DOUBLER, REPAIR FILLER & 03EA REPAIR ANGLES FAB PER SRM57-10-00 VI FIG 27 R40. NEW FAB REPAIR DOUBLER, REPAIR FILLER & 3EA REPAIR ANGLES INSTALLED AT RT WING FIXED L/E COMPT STA XORS 538 INTERIOR AREA PER SRM 57-10-00 VI FIG 27 REV 40.