What was found
INSPECTION TYPE:C AFT CARGO AT STATION 1894 LONGERON 40 RT CORROSION FOUND ON LONGERON AREA AS MARKED. CORROSION LONGERON REMOVED PER SRM 53-10-00 FIG 1 VI REV35. HFEC C/O IAW NDTSPM R13 PT 06.10-01.001 ON TRIMMED EDGE AND FOUND NO CRACK EVIDENT. REPAIR LONGERON AND REPAIR SPLICE FAB PER SRM 53-10-00 FIG 2 VI REV 35 FPI C/O PER DPS 4.707 REV AW ON FABRICATED REPAIR PART AND FOUND NO CRACK EVIDENT. NEW REPAIR SPLICE INSTALLED PER SRM 51-31-01 VII REV 35.