What was found
INSPECTION TYPE-C, LT WING ANTI-ICE TELESCOPIC DUCT LOWER DOOR FWD AREA FOUND CHAFING MARK. LT WING ANTI-ICE TELESCOPIC DUCT LWR DOOR PANEL REMOVED IAW AMM 20-50-02R53. CHAFING MARK REMOVED FOUND EXCEED LIMIT IAW SRM 57-00-01 VIR 35. NEW PANEL FABRICATED IAW DWG ARM 0078. HEAT TREAT TO T62 IAW DPS7.00-1 HRB 75.4 IS ACCEPTABLE LIMITS IAW DPS1.05-3. FASTENER HOLES PICKUP IAW SRM 51-31-01VII R35. PROTECTED & PAINTED IAW SRM51-21-01VII R35. INSTALLED IAW AMM 20-50-03R53.