What was found
INSPECTION TYPE-C, RT WING OB FLAP IB HINGE (FLAP MOUNTED) UPPER MOUNTING POINT FWD OB NR 2 BORE HOLE FOUND CORRODED AS MARKED. CORRODED IN AFFECTED AREA REMOVED. ORG DIA 0.599", FINAL DIA 0.6725". FPI C/O ON REWORK AREA & FOUND NO CORROSION EVDNT. BORE FINAL DIA OF 0.6725" EVAL. & FOUND ACCEPTED IAW EN1182-08. FLAP PEENING, CADMIUM PLAT & PAINTING C/O ON REWORK AREA. BUSHING & WASHER FAB AND HEAT-TREATED. BUSHING INSTL WITH BUSHING LINE REAM TO DIA: 0.583". NEW WASHER INSTL.