What was found
INSPECTION TYPE-C, RT HORIZ STAB BARREL NUT BORE NR1 FOUND CORRODED EXISTING SLEEVE BUSHING REMOVED IAW EO MD11-5510-19409M. CORROSION AT BORE REMOVED IAW SRM 51-21-01 VII REV 35. BORE REAM TO 1.549" DIA, REMAINING BLEND OUT 0.050" DEEP, BOTTOM SURFACE CLEANED & REMAINING MAT'L THK CHK MIN. 0.290" THICK. BORE FOUND EXCEEDING LIMITS IAW EO. REPAIRED B/N BO RE NR 01RH WAS ACCOMP IAW EN 1186-08 & IS ACCEPT IAW EO MD11-5510-30008A.