What was found
INSPECTION TYPE-C, LT WING OB FLAP IB AFT HINGE UPPER MOUNTING FOUND CENTER BORE CORRODED. LT AFT OB FLAP IB HINGE UPPER MOUNTING CENTER BORE CORROSION REMOVED IAW BSOPM 20-11-02 REV 61 FPI C/O IAW DAC NDT SPM REV 13 PT 08 ON REWORKED AREA & FOUND NO CRACK & NO CORROSION EVIDENT. LT AFT OB FLAP I B HINGE UPPER MOUNTING CENTER BORE FINAL DIA OF 2.020" EVALUATED & FOUND ACCEPTED IAW EN1288-08. FLAP PEENING C/O ON RWK AREA IAW EN1288-08.