What was found
INSPECTION TYPE-C, LT WING OB FLAP IB AFT HINGE LOWER MOUNTING FOUND 02EA BORE RUSTY. LT AFT OB FLAP IB HINGE LOWER MOUNTING FWD & AFT BORE CORROSION REMOVED IAW BSOPM 20-11-02 REV 61.FPI C/O IAW DAC NDT SPM REV 13 PART 0 8 ON REWORKED AREA. FOUND NO CRACK/CORROSION EVIDENT. REWORKED BO RES(02EA) REAMED IAW EN 1288-08.REWORKED AREA ETCH INSPECTED & FOUND SATIS IAW EN 1288-08.BUSHINGS(02EA) FAB & INSTALLED IAW EN 1288-08.