What was found
INSPECTION TYPE-1C, FOUND CORROSION IN NR 21 LT BARREL NUT BORE HOLE. REMOVED CORROSION, FABRICATED BUSHING, AND INSTALLED BUSHING IAW UPS EO MD11-5510-19409-N AND SAA TRAVELER 80538620001