What was found
INSPECTION TYPE:C, REFERENCE TO EO MD11-5310-27496D, UNABLE TO OBTAIN SUPPORT ASSY ABA7430 -1 OR THE RAW MATERIAL DUE TO LONG LEAD TIME SUPPORT FABRICATED IAW DWG ABA7430 & EN NR 1172-08. FPI C/O IAW DP S 4.707 REV 'AW'. NO CRACK EVIDENT ON FABRICATED FLOOR SUPPORT. FLOOR SUPPORT REPROTECTED IAW SRM51-21-01 VII R35. FLOOR SUPPORT LOCATED & INSTALLED IAW DWG SP11530074 & EN 1172-08 AND REFER EO MD11-5310-2 7496-D.