What was found
INSPECTION TYPE:N/A, DENT AND CRACK DAMAGE FOUND ON FUSELAGE SKIN AT STA 1741 TO STA 1761 L LT, LONGERON 38 AND 39. DAMAGED AREA TRIMMED OUT, LENGTH = 12" X WIDTH = 5.5" AND REPAIRED AS PER SRM 53-20-00 FIG 2, VOL I, REV 40, AND UPS EO MD11-5330-18894C.