As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A CTR CARGO FRAME SHEAR CLIP AT STATION 1681 BILGE AREA L52 FOUND CORROSION. FRAME SHEAR CLIP CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01 VOL II REV 40. MATERIAL REMOVED 0.008" ORIGINAL THK 0.071" REMAINED 0.068" FOUND WITHIN LIMITS PER SRM 53-00-01 FIG 2 VOL I REV 40.