What was found
INSPECTION TYPE:N/A CTR CARGO FRAME AT STA 1661 BILGE AREA BETWEEN L51 LT & RT FOUND CORROSION. FRAME SHEAR CLIP CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21- 01. MATERIAL REMOVED 0.005" ORIGINAL THK 0.071" REMAINED 0.066" FOUND WITHIN LIMIT PER SRM 53-00-01 FIG 2.