As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A CTR CARGO FRAME AT STA 1721 BILGE ARE L52 FOUND CORROSION. FRAME CHANNEL AND SHEAR CLIP CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01. MATERIAL REMOVED 0.007" ORIGINAL THK 0.071" REMAINED THK 0.064" FOUND WITHIN LIMITS PER SRM 53-30-00.