What was found
INSPECTION TYPE:C RT WING - NR 7 SLAT T/E WEDGE HAS 1(EA) DENT OUT OF LIMITS DUE TO PROXIMITY 100.26 INCHES FROM O/B END, 1.6 INCH FROM T/E, .50 INCH DIA (MARKED GROUP 1). REMOVED SURFACE FINISH, FABRICATED AND BONDED 1EA DOUBLER IAW SRM 57-43-02, REPAIR 1 FIG 201 PAGE 201 SRM 51-70-10 REPAIR 2 PAGE 203 "E" FIG 201.