What was found
INSPECTION TYPE:C RT WING NR 8 SLAT T/E WEDGE HAS 1 (EA) DENT OUT OF LIMITS DUE TO PROXIMITY 36.5 INCHES FROM O/B END, 1.2 INCH FROM T/E, .65 INCH DIA (MARKED GROUP 1). REMOVED SURFACE FINISH, FABRICATED AND BONDED 1EA DOUBLER IAW SRM 57-43-02 REPAIR NR 1 FIG 201 PAGE 201 SRM 51-70-10 REPAIR NR 2 PAGE 203 "E" FIG 201.