INSPECTION TYPE:C RT WING, NR 9 SLAT T/E EDGE HAS 1 DENT OUT OF LIMITS DUE TO PROXIMITY 57.1 INCH FROM INBD END, 8.3 INCH FROM T/E, .70 INCH DIA. REMOVED SURFACE FINISH, FABRICATED AND BONDED 1 DOUBLER IAW SRM 57-43-02 REPAIR NR 1 FIG 201 PAGE 201 SRM 51-70-10. REPAIR NR 2 PAGE 203 'E" FIG 201.