As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FRAME DENTED BS 1300 STR 26L. TRIM OUT DAMAGE AREA, DIM:L=0.530 INCH W=1.550 INCH IAW EA 757-5362-27-A1822 STEP1. HFEC INS TRIMMED AREA PER NTM51-00-19 PT6. NO CRACK IND NOTED. ENLARGED CUTOUT BY 0.04 INCH AS INS CUT IAW EA 757-5362-27-A1822 STEP 2 REPAIRED PER FINAL EA 757-5362-27-A1822 AND UPS EO B757-5310-32252-A WITH NO DEVIATIONS.