What was found
INSPECTION TYPE:C LT WING-NR 4 SLAT T/E WEDGE HAS 1 DENT OUT OF LIMITS DUE TO PROXIMITY-97.5 INCH FROM OTBD END, 2.1 INCH FROM T/E (MARKED GRP 3). REMOVED TOPCOAT TO PREPARE FOR BOND OF DOUBLER IAW SRM 57-43-02 AND SRM 51-70-10 PRE NR 2,E, (C)PG203, FIG201. CLEANED AND PREPPED AREA TO PREPARE BOND IAW SRM 57-43 02 AND 51-70-10, REP NR 2, E, (C)PG 203 FIG201. FABRICATED DOUBLER, 2024-T81, (BTCH NR 5R00518001 PO NR ST95000854) IAW SRM 57-43-02 AND 51-70-10, REP NR 2,E(C) PG 203 FIG201. PREP MAT SURF BOEGEL (BTCH NR 0001489157, PO MST0026211) PRIMER BMS-5-89, TYPE 1.