What was found
INSPECTION TYPE:C- LT WING, NR 5 SLAT T/E WEDGE HAS 2 DENTS OUT OF LIMITS DUE TO PROXIMITY 71.75 INCH FROM INBD END, 4.5 INCH FROM T/E, 1.8 INCH DIA. REMOVED TOPCOAT PREP FOR BOND OF DOUBLER IAW SRM 57-43-02/51-70-10, REPAIR NR 2 E(C) PG 203 FIG 201. CLEANED/PREP FOR BOND IAW SRM 57-43-02/51-70-10, REPAIR NR 2 E(C) FIG 201. FAB DOUBLER IAW SRM 57-43-02/51-70-10, REP NR 2, E(C) PG 203 FIG 201.