What was found
INSPECTION TYPE:C FRAME DENTED BS 1540, STR 25R. TRIMMED OUT DAMAGED AREA IAW B757-200 SRM 53-00-07-2R, STEP 1. HFEC INSP TRIMMED AREA PER NTM51-00-19 PT6 NO CRACK INDICATION NOTED. PERFORMED INS CUTOUT OF .04 INCH AROUND TRIMMED OUT AREA IAW B757-200 SRM 53-00-07-2R5, STEP 2. AFTER INS CUT MEASURES L=1.05",W=1.15". 4. REMOVED PROD SPLICE FROM FRAME STA 154 BETWEEN STR 24 & 25 IAW B757-200 SRM 53-00-07-2R SHT 8 DETAIL III.