What was found
INSPECTION TYPE:C FRAME DENTED BS 1380 STR 25L. TRIMMED DAMAGE AREA, MEASURES L=.900" W=1.05" IAW SRM 53-00-07-2R5 STEP 1. HFEC INSP TRIMMED AREA PER NTM 51-00-19 PT6, NO CRACK INDICATION NOTED. PERFORMED INS CUT BY 0.04" NEW DIMENSION L=.940" W=1.09". FAB FRAME REPAIR ANGLE ON MAE TRAV T9/776079 LOCATE, DRILL TREAT & PRIMED. PERFORMED WORK PER SRM STEP 8, 53-00-07-2R5 EO INCORPORATED B757-5310-32290-A.