As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C FRAME DENTED - BS 1320, BETWEEN STR 25-26R. TRIMMED OUT DAMAGED AREA IAW SRM 53-00-07-2R STEP 1. HFEC INSPECTED TRIMMED AREA PER NTM 51-00-19 PT.6 NO CRACKS. TRIMMED OUT DAMAGED AREA IAW SRM 53-00-07-2R5 STEP 2. AFTER INSURANCE CUTOUT MEASURES L=1.18 W=1.02". REMOVED PROD SPLICE FROM STA 1320 IAW SRM 51-40-01. REMOVED STR CLIPS FROM STA 1320.