What was found
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATTACH ANGLE FOUND CRACKED JUST AT STA 1580 LBL 75. CRACK 1 INCH LENGTH. MAIN DECK FLOOR SUPPORT ATTACH ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 AT BS 1580 LBL 75 AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATTACH ANGLE FOUND CRACKED JUST AT STA 1580 LBL 75. CRACK 1 INCH LENGTH. MAIN DECK FLOOR SUPPORT ATTACH ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 AT BS 1580 LBL 75 AREA.