What was found
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATTACH ANGLE CRACK JUST AT STA 1580 RBL 75 CRACK 1.125 INCH LENGTH. MAIN DECK FLOOR SUPPORT ATTACH ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 JUST AT STA 1580 RBL 75.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATTACH ANGLE CRACK JUST AT STA 1580 RBL 75 CRACK 1.125 INCH LENGTH. MAIN DECK FLOOR SUPPORT ATTACH ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 JUST AT STA 1580 RBL 75.