What was found
DURING 'D' CHECK, MAINTENANCE FOUND FLOURESCENT LIQUID PENETRANT INSPECTION OF FASTENER HOLES ON BS 660 FRAME AT OR NEAR STRINGER 19R EXHIBIT A CRACK INDICATION FROM SCREW HOLE TO FASTENER HOLE. INSTALLED REPAIR IAW SRM 51-40-3, 51-30-2, AND 51-10-2.