What was found
DURING 'D' CHECK, MAINTENANCE REPORTED CORROSION ON FLOOR BEAM AT STA 1030, RBL 41, WL 208. REPAIRED FLOOR BEAM PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.