What was found
DURING D-CHECK, MAINTENANCE FOUND CORROSION ON STRINGER 3L, STA 970-1130. INSTALLED REPAIR PER SRM 51-10-06, 51-30-02, 51-10-02, 51-40-05, 53-10-01, 53-10-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, MAINTENANCE FOUND CORROSION ON STRINGER 3L, STA 970-1130. INSTALLED REPAIR PER SRM 51-10-06, 51-30-02, 51-10-02, 51-40-05, 53-10-01, 53-10-04.