What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON THE INNER SKIN AT STATION 760 TO 785 BETWEEN STRINGERS S8R AND S10R. MAINTENANCE REMOVED THE CORROSION, HFEC INSPECTED AREA, FLAP PINNED AREA AND REINSTALLED SURFACE FINISH IAW EO 95-2345.