What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON NUTPLATES AT BOTTOM OF FLANGE OF FLOORBEAM AT STATION 660, RBL 64 TO LBL 64, WL 208.1. MAINTENANCE REMOVED TOP OF FLOORBEAM FROM WEB RBL 17 OUTBOARD TO END OF BEAM, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-8.