What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON NUTPLATES AT BOTTOM OF FLANGE OF FLOORBEAM AT STATION 680 FROM LBL 64 TO RBL 64 AND WL 208.1. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 51-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON NUTPLATES AT BOTTOM OF FLANGE OF FLOORBEAM AT STATION 680 FROM LBL 64 TO RBL 64 AND WL 208.1. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 51-10-8.