What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON STRINGER FITTING NR 2R AT STATION 740 AFT SIDE. MAINTENANCE REMOVED THE CORROSION ON NR 2R STRINGER AT STATION 704 AFT SIDE, FOUND TO BE OUT OF LIMITS, WORK ACCOMPLISHED PER SRM 51-10-6, ORDERED NEW PART AND INSTALLED IAW SRM 51-30-2.