What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON STRINGER 3R AT STATION 950 TO 1183. MAINTENANCE REMOVED THE DAMAGED AREA AND REPAIRED PER SRM 53-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON STRINGER 3R AT STATION 950 TO 1183. MAINTENANCE REMOVED THE DAMAGED AREA AND REPAIRED PER SRM 53-10-2.