What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION ON THE FLOORBEAM AT STATION 720, RBL 51 AND RBL 61, WL 208. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED ALL WORK DONE PER SRM 51-10-1, 51-10-6, 51-10-2, 51-30-2 AND UPS EO B727-5310-6839A.