What was found
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION AROUND FASTENER HOLES UPPER AND LOWER FLANGES OF FLOORBEAM AT STATION 344, RBL 11 TO RBL 20, WL 208.1. MAINTENANCE FABRICATED REPAIR PARTS AND INSTALLED IAW UPS EO B727-5310-6844A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 'D' CHECK, MAINTENANCE FOUND CORROSION AROUND FASTENER HOLES UPPER AND LOWER FLANGES OF FLOORBEAM AT STATION 344, RBL 11 TO RBL 20, WL 208.1. MAINTENANCE FABRICATED REPAIR PARTS AND INSTALLED IAW UPS EO B727-5310-6844A.