What was found
WHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE EXPANSION LINK FITTING AT STATION 740, LBL 45 AND WL 206. MAINTENANCE REMOVED AND REPLACED THE EXPANSION LINK FITTING PER SRM 51-10-6, 51-30-2, 51-30-5, 53-10-1 AND OHM 20-50-3 AND 20-50-2.