What was found
WHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE UPPER SKIN OF THE FUEL CELL AT STATION 868 - 870, LBL 67 - 65 AND WL 190. MAINTENANCE REMOVED THE CORROSION FROM THE CENTER TANK SKIN, BLENDED AREA, INSTALLED FILLER WASHERS IAW SRM 51-10-2, 51-20-151 AND UPS EO 727-57-1351.