What was found
WHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE BOTTOM FLOOR BEAM AT STATION 344, RBL 0 TO 45 AND WL 208. MAINTENANCE BLENDED OUT THE DAMAGE AND INSTALLED THE REPAIR STRAP IAW UPS EO 727-53-1588 AND SRM 53-10-1 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE BOTTOM FLOOR BEAM AT STATION 344, RBL 0 TO 45 AND WL 208. MAINTENANCE BLENDED OUT THE DAMAGE AND INSTALLED THE REPAIR STRAP IAW UPS EO 727-53-1588 AND SRM 53-10-1 AND 51-30-2.