DURING 'C' CHECK, MAINTENANCE FOUND FILLER PLATE CORRODED ON 25 G-BEAM BS 259 TO 276. REPLACED INTERCOSTAL PER SRM 51-10-1, 51-30-2, 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 'C' CHECK, MAINTENANCE FOUND FILLER PLATE CORRODED ON 25 G-BEAM BS 259 TO 276. REPLACED INTERCOSTAL PER SRM 51-10-1, 51-30-2, 51-10-2.