What was found
WHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON CREASE BEAM AT FASTENER HOLES, BS 304 TO 344, RBL 58, WL 208 UPPER AND LOWER. INSTALLED FABRICATED PARTS IAW SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON CREASE BEAM AT FASTENER HOLES, BS 304 TO 344, RBL 58, WL 208 UPPER AND LOWER. INSTALLED FABRICATED PARTS IAW SRM 51-40-3.