What was found
WHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM AT BS 560, RBL 6, WL 199. REMOVED AND INSTALLED REPAIR SECTION IAW UPS EO NR B727-5310-7026A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN SI CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM AT BS 560, RBL 6, WL 199. REMOVED AND INSTALLED REPAIR SECTION IAW UPS EO NR B727-5310-7026A.