What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON CREASE BEAM BS 306-312 RBL 56, WL 208 AT FLOORBOARD FASTENER HOLES. REPAIRED IAW SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON CREASE BEAM BS 306-312 RBL 56, WL 208 AT FLOORBOARD FASTENER HOLES. REPAIRED IAW SRM 51-40-3.