What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION AROUND NUTPLATES ON FLOORBEAM AT STA 277 WL 208 RBL 15 TO 40. REPAIRED IAW SRM 53-10-1, 51-40-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION AROUND NUTPLATES ON FLOORBEAM AT STA 277 WL 208 RBL 15 TO 40. REPAIRED IAW SRM 53-10-1, 51-40-4.