What was found
WHILE IN FOR C-CHECK, MAINT FOUND SHORT AND MISSING FASTENERS ON FRAME STA 294 LBL 55 WL 280. REMOVED AND REPLACED SHORT FASTENERS AND REPLACED MISSING FASTENERS. FOUND STRINGER CLIP TO BE CRACKED. REMOVED CRACKED STRINGER CLIP AND REPLACED WITH FABRICATED STRINGER CLIP IAW SRM 51-20-1, 51-10-2, 51-30-2 AND 51-30-5.