What was found
WHILE IN FOR C-CHECK, MAINT FOUND CORR C53-224-01.00-01, ON STRINGER 9 RT STA 390, 400 AND 440 TO 480. REMOVED CORR IAW SRM 53-10-1 AND FOUND AREA AT 396 RT TO BE OUT OF LIMITS. FABED REPAIR PARTS AND INSTALLED IAW SRM 53-10-2, 53-10-3.