What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION AROUND THE NUT PLATES AT STATION 803, RBL 6 AND WL 148. MAINTENANCE REMOVED THE DAMAGED AREA, FABRICATED NEW INTERCOSTAL AND INSTALLED IAW SRM 53-10-1, 51-10-6 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION AROUND THE NUT PLATES AT STATION 803, RBL 6 AND WL 148. MAINTENANCE REMOVED THE DAMAGED AREA, FABRICATED NEW INTERCOSTAL AND INSTALLED IAW SRM 53-10-1, 51-10-6 AND 51-30-2.