What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON THE FASTENER HOLES, COMMON TO FRAME AT STATION 360 LBL 48 WL 165, BS 360 LBL 45 WL 165, BS 360 LBL 35 WL 158 AND BS 360 RBL 21 WL 151. MAINTENANCE REPAIRED PER UPS EO 727-53-1667.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON THE FASTENER HOLES, COMMON TO FRAME AT STATION 360 LBL 48 WL 165, BS 360 LBL 45 WL 165, BS 360 LBL 35 WL 158 AND BS 360 RBL 21 WL 151. MAINTENANCE REPAIRED PER UPS EO 727-53-1667.