What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION ON THE DOUBLER AT STATION 307.5 TO STA 316, LBL 12.5 WL 181 TO 169. MAINTENANCE REMOVED TRIPLER AND REMOVED CORROSION ON TRIPLER. CORROSION FOUND BEYOND LIMITS, FABRICATED NEW DOUBLER AND TRIPLER, FINAL INSTALLATION PER SRM 51-10-6, 51-30-2, 51-20-4, MM 51-20-0 AND UPS 727-53-1671.