What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION (C53-224-01.06-03) ON INTERIOR SKIN STA 1070-1090 STR 10-14 RT FROM UNDER WINDOW CASTING AND REPAIR DOUBLERS. REPLACED WINDOW FRAME PER SRM 51-10-1, 51-10-2, 51-10-6, 51-30-2, 53-10-4 AND 51-20-4.