What was found
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION (C53-224-01.05-01) ON FLOOR BEAM STA 420 RBL 45-65 WL 208 LWR SIDE OF UPPER CHORD. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REPAIRED IAW UPS E.O. B727-5310-7455A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN FOR SI CHECK, MAINTENANCE FOUND CORROSION (C53-224-01.05-01) ON FLOOR BEAM STA 420 RBL 45-65 WL 208 LWR SIDE OF UPPER CHORD. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REPAIRED IAW UPS E.O. B727-5310-7455A.